• Monofásica 100 – 240 - 277 Vac / 140 – 340 Vdc
  • Output Load:12 Vdc 10A; 24 Vdc 10A
  • Battery charging: 12 Vdc 15A; 24 Vdc 10A
  • Modbus RTU
  • Proteção IP20 (EN/IEC 60529)
com IVA
403.44€

sem IVA
328.00€
Sku: CBI2501224A
Type de produit: Fontes DC-UPS
Vendeur: ADELSYSTEM

CBI2501224A

DC-UPS All In One Input 115-230-277Vac, Output 12-24V 280W

  • Input: Single-phase 100 – 240 - 277 Vac / 140 – 340 Vdc
  • Output Selectable Load: 12 Vdc 10A; 24 Vdc 10A
  • Two output: 1 Continuous, 1 Dynamic: On/Off by Modbus
  • Output Battery charging: 12 Vdc 10A; 24 Vdc 10A
  • Two load outputs: one static; one dynamic for: On/Off, Dimmer (LED, DC brush motors), Fuse Breaker, PC shutdown and more
  • Modbus RTU for Monitoring, Configuration, History and Alarms
  • ADELBus: integrated monitoring and control of ADELSystem devices such as MRF10x e-Fuses and display
  • Suitable for the following battery types: Open Lead Acid, Sealed Lead Acid (AGM/VRLA), lead Gel, Li-Ion and NiCd/NiMH
  • Battery Care: Automatic diagnostic of battery state-of-charge (SoC) and state-of-health (SoH)
  • Charging curve IUoU, constant voltage and constant current
  • Five charging levels: Recovery, Boost, Absorption, Float (Forced trickle / Forced float / Auto float-trickle), and Refresh
  • Battery purification for battery reinvigoration
  • Protected against short circuit and reversed polarity
  • Signal output (contact free) for: discharged or damaged battery, Mains or Back-up, rectifier failure
  • Protection degree IP20 - DIN rail; Space savin
Especificações
DC-UPS-Range

Main features

  • Output current 2,5 A ÷ 20 A even in case of power outage (shortage)
  • Automatic allocation of available power between load and battery charging up to twice-rated output current
  • Power output: 120W, 240W, 280W, 500W, 600W
  • Visual indication of "power shortage","defective battery", "battery voltage< 30%", "battery charging level", self-diagnostic with flashing LED code
  • Warning relays: "main or back-up" and "defective/flat battery" with galvanic isolated output contacts NO-NC
  • 3 charging levels: "boost", "trickle" and "recovery"
  • Self-diagnosis "overload", "battery sulfutation", "reverse polarity connection", "elements in short circuit", "protection against short circuit"
  • Compatible with a remote connection to select "boost" or "trickle" charging mode
  • Accessories upon request: external temperature sensors; voltage drop compensation; remote LED display
  • Compact dimensions
  • Ambient temperature operation: -25 ÷ 70°C
  • IP 20
 

Start Battery Button feature

  1. AC MAIN FAILURE
  2. DC-UPS continues to power backup through the BATTERY
  3. AC Power failure longer than expected. 
  4. Replace the battery with a new one
  5. Push the START BATTERY button for 3 seconds
  6. Production continuity is guaranteed
 
 
Diagrama Funcional
CBI2501224A_design
CBI2801224A_ligação
Diagrama CBI2501224A

Entrega Normal | 5 a 7 dias úteis

Entrega Urgente | 3 a 5 dias úteis

*salvo rutura de stock

Trabalhamos intensamente cumprir os prazos de entrega anunciados. No entanto, enfrentamos uma escassez global relativamente a alguns componentes e fabricantes.
Em caso de dúvidas ou preocupações, entre em contacto connosco para garantir o tempo de entrega.
Poderemos aconselhar sobre a disponibilidade de hardware alternativo e fornecer recomendações de componentes disponíveis para opções de envio mais rápidas.